Shut down Test

Use the following procedure for the shutdown test:

RAILA:

  1. Set the load current to 50 A.

  2. Make sure all default jumpers(J1-J9) settings as shown in Table 4-3 .

  3. Connect probes Enable (TP11), VOUTA (J15, BNC cable), PWM1 (TP31), and VOUT_A_RDY (TP22).

  4. Set up the time / div on the oscilloscope to: 500 μs/div.

  5. Set the trigger to channel 1 ‘Enable_A’ on the falling edge at about 1 V.

  6. Turn on the power supply (with the voltage set to 12 V and the current limit set to 10 A).

  7. Slide the enable switch ‘S1’ to the ON position and measure output voltage as 0.88V.

  8. Turn-off the switch "S1" to OFF position.

GUID-20210305-CA0I-RST8-NN93-BCTRQ2CPCTVZ-low.jpgFigure 6-3 VOUTA Enable OFF, Immediate-off
GUID-20210305-CA0I-PQK9-KXDJ-C2SCTQL9MCFV-low.jpgFigure 6-4 VOUTA Enable OFF Soft-off with TOFF delay=1ms

RAILB:

  1. Set the load current to 10 A.

  2. Make sure all default jumpers (J1-J9) settings as shown in Table 4-3.

  3. Connect probes Enable_B (TP12), VOUTB (J16, BNC cable), BPWM1 (TP55), and VOUT_B_RDY (TP23).

  4. Set up the time / div on the oscilloscope to: 500 μs/div.

  5. Set the trigger to channel 1 ‘Enable_B’ on the falling edge at about 0.8V.

  6. Turn on the power supply (with the voltage set to 12 V and the current limit set to 5 A).

  7. Slide the enable switch ‘S2’ to the ON position and measure output voltage as 0.8V.

  8. Turn-off the switch "S2" to OFF position.

GUID-20210304-CA0I-P01C-PWK5-TK0H0ZQ6XGV6-low.jpgFigure 6-5 VOUTB Enable OFF, Immediate-off
GUID-20210304-CA0I-BR1D-VQSC-W8NZFKMJLMS0-low.jpgFigure 6-6 VOUTB Enable OFF Soft-off with TOFF delay=1ms