SLVUCP9A November   2023  – March 2024 TPS25751

 

  1.   1
  2.   Description
  3.   Get Started
  4.   Features
  5.   Applications
  6.   6
  7. 1Evaluation Module Overview
    1. 1.1 Introduction
    2. 1.2 Kit Contents
    3. 1.3 Specification
    4. 1.4 Device Information
  8. 2Hardware
    1. 2.1 Power Requirements
    2. 2.2 Setup
    3. 2.3 Header Information
    4. 2.4 Jumper Information
    5. 2.5 LED Information
    6. 2.6 Test Points
    7. 2.7 Switches/Push Buttons
  9. 3Software
    1. 3.1 Software Description
      1. 3.1.1 Software Installation
      2. 3.1.2 Web Browser
      3. 3.1.3 Native Application
    2. 3.2 Software Development
    3. 3.3 Using the TPS25751 Application Customization Tool
      1. 3.3.1 Default View
      2. 3.3.2 Selecting a Configuration
      3. 3.3.3 Filling Out the Questionnaire
      4. 3.3.4 Advanced Configuration Mode
      5. 3.3.5 Flashing Configuration onto EVM
      6. 3.3.6 Additional Settings
        1. 3.3.6.1 Generating a New Configuration
        2. 3.3.6.2 Exporting and Importing Settings
        3. 3.3.6.3 Generating the Binary
        4. 3.3.6.4 Generating the VIF file
  10. 4Application Specific Use Case
    1. 4.1 Application Specific General Overview
    2. 4.2 TPS25751EVM and BQ257xxEVM Setup
      1. 4.2.1 Setting up with BQ25756(E)EVM
        1. 4.2.1.1 Hardware Setup with BQ25756(E)EVM
        2. 4.2.1.2 Software Setup with BQ25756(E)EVM
      2. 4.2.2 Setting up with BQ25792/8EVM
        1. 4.2.2.1 Hardware Setup with BQ25792/8EVM
        2. 4.2.2.2 Software Setup with BQ25792/8EVM
      3. 4.2.3 Setting up with BQ25713EVM
        1. 4.2.3.1 Hardware Setup with BQ25713EVM
        2. 4.2.3.2 Software Setup with BQ25713EVM
    3. 4.3 Liquid Detection and Corrosion Mitigation Overview
      1. 4.3.1 Liquid Detection/Corrosion Mitigation Hardware Setup
      2. 4.3.2 Liquid Detection/Corrosion Mitigation Software Setup
  11. 5Hardware Design Files
    1. 5.1 Schematics
    2. 5.2 PCB Layouts
    3. 5.3 Bill of Materials (BOM)
  12. 6Additional Information
    1. 6.1 Trademarks
    2. 6.2 Electrostatic Discharge Caution
    3. 6.3 Terminology
    4. 6.4 Device Support
      1. 6.4.1 Third-Party Products Disclaimer
      2. 6.4.2 Supplemental Content
    5. 6.5 Documentation Support
      1. 6.5.1 Documentation Support
    6. 6.6 Receiving Notification of Documentation Updates
    7. 6.7 Support Resources
  13. 7Revision History

Flashing Configuration onto EVM

The Application Customization Tool is used to directly load a configuration onto the TPS25751EVM. Connect J4 Type-C connector with a cable (both USB-A to USB-C or USB-C to USB-C® cables work) to a laptop or computer with the Application Customization Tool open. Make sure the TPS25751EVM is properly powered either through J2 Type-C connector to a 15V-20V Type-C adapter or with a bench power supply. See the figure below for reference.

GUID-20240301-SS0I-HHD8-VPJK-GMMFMCJ9RQQ5-low.svg Figure 3-5 TPS25751EVM Connection with PC
Note: When flashing a configuration onto TPS25751EVM, connect the TPS25751EVM with a power source such as a PD adapter or bench power supply. For evaluation battery charging applications with the BQ257xxEVM, connect the BQ EVM after the TPS25751EVM has a proper configuration loaded.

Open the Application Customization Tool and complete the questionnaire, refer to Section 3.3.3 for details on each question. Once the questionnaire is complete and the TPS25751EVM is connected properly, click on Options → Serial Port Configuration to make sure the correct COM port is selected. See the figure below for reference.

GUID-20231109-SS0I-ZF60-5P51-X8ZS4HLDFH4W-low.svg Figure 3-6 Serial Port Configuration Settings

If the TPS25751EVM is unable to connect to the Application Customization Tool, then go through the following debug recommendations:

  1. Make sure the cable connecting the computer to the TPS25751EVM supports data.
  2. Make sure the power source (whether it's from a Type-C adapter or bench power supply) is supplying 15V-20V. TPS25751EVM cannot power on properly if the power source is less than 15V.
  3. Make sure only one tab of the Application Customization Tool is running at any given time. Multiple tools running simultaneously can cause communication issues.

Once the questionnaires are completed and the TPS25751EVM is connected to the Application Customization Tool, click on Flash To Device → Flash to device from current configuration.

GUID-20231109-SS0I-5DFW-7DG6-1XGLZS3R1ZQS-low.svg Figure 3-7 Flash to Device from Current Configuration
GUID-20231109-SS0I-PRN4-XK4K-ZD5RX9HJS5CW-low.svg Figure 3-8 Flash to Device from Current Configuration
GUID-20231109-SS0I-4KQB-5JRJ-JSFWJWNXTJTR-low.svg Figure 3-9 Flash to Device from Current Configuration
Note: When the tool is flashing the configuration, DO NOT connect or disconnect any cables on the TPS25751EVM. Connecting or disconnecting any cables can cause errors when flashing.