SLAU723A October 2017 – October 2018 MSP432E401Y , MSP432E411Y
HIB Tamper Log 0 (HIBTPLOG0), offset 0x4E0
HIB Tamper Log 2 (HIBTPLOG2), offset 0x4E8
HIB Tamper Log 4 (HIBTPLOG4), offset 0x4F0
HIB Tamper Log 6 (HIBTPLOG6), offset 0x4F8
The HIB Tamper Log (HIBTPLOG) even registers capture the time information during a tamper event. Up to four tamper logs can be stored. The HIBTPLOG registers are cleared when the TPCLR bit is written in the HIBTPCTL register.
NOTE
It is recommended that an external oscillator is used if accurate time stamps on the tamper log are critical.
HIBTPLOG0 is shown in Figure 6-32 and described in Table 6-27.
Return to Summary Table.
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
TIME | |||||||||||||||||||||||||||||||
R-0x0 | |||||||||||||||||||||||||||||||