SLAU723A October 2017 – October 2018 MSP432E401Y , MSP432E411Y
User Register 0 (USER_REG0), offset 0x1E0
User Register 1 (USER_REG1), offset 0x1E4
User Register 2 (USER_REG2), offset 0x1E8
User Register 3 (USER_REG3), offset 0x1EC
These registers each provide 32 bits of user-defined data that is nonvolatile. Bits can only be changed from 1 to 0. The reset value shown only applies to power-on reset when the register is not yet committed; any other type of reset does not affect this register. Once committed, the register retains its value through power-on reset. The only way to restore the factory default value of this register is to perform the "Recover Locked Device" sequence detailed in the JTAG section.
USER_REG is shown in Figure 7-44 and described in Table 7-46.
Return to Summary Table.
31 | 30 | 29 | 28 | 27 | 26 | 25 | 24 | 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
DATA | |||||||||||||||||||||||||||||||
R/W-0xFFFFFFFF | |||||||||||||||||||||||||||||||