0x34 ACTIVE_CONTRACT_PDO Register

Table 2-7 0x34 ACTIVE_CONTRACT_PDO Register
AddressNameAccessLengthUnique Per PortPower-Up Default
0x34ACTIVE_CONTRACT_PDORO6yesCleared on disconnect, Hard Reset, or PR_Swap.
Table 2-8 0x34 ACTIVE_CONTRACT_PDO Register Bit Field Definitions
BitsNameDescription
Bytes 5-6: Source Properties
15:10Reserved
9:0firstPDOControlBitsContains bits 29:20 of the first PDO. It does not matter which PDO was selected, this field is always drawn from the first PDO.
Bytes 1-4: Contract PDO (treated as 32-bit little endian value)
31:0ActivePDOPower data object. This field contains the contents of the PDO Requested by PD Controller as Sink and Accepted by Source, after it is Accepted by Source.