AFE4410

現行

適用於穿戴式光學心率監控和生物感測且具有 FIFO 的低功耗整合式 AFE

產品詳細資料

Applications Optical-HRM Number of input channels 3 Resolution (Bits) 22 Number of LEDs 4 Interface type I2C, SPI Operating temperature range (°C) -20 to 70 Rating Catalog
Applications Optical-HRM Number of input channels 3 Resolution (Bits) 22 Number of LEDs 4 Interface type I2C, SPI Operating temperature range (°C) -20 to 70 Rating Catalog
DSBGA (YZ) 30 4.8 mm² 2.4 x 2
  • Accurate, Continuous Heart-Rate Monitoring:
    • Up to 100-dB Dynamic Range for Accurate Heart-Rate Detection
    • Low Current for Continuous Operation on a Wearable Device With a Typical Value:
      • 30 µA for an LED, 25 µA for the Receiver
  • Transmitter:
    • 4 LEDs in Common Anode Configurations
    • 8-Bit Programmable LED Current to 200 mA
    • Mode to Fire Two LEDs in Parallel
    • Programmable LED On-Time
    • Simultaneous Support of 3 LEDs for Optimized SpO2, HRM, or Multiwavelength HRM
    • Average Current of 30 µA Adequate for a Typical Heart-Rate Monitoring Scenario:
      • 20-mA Setting, 60-µs Pulse Duration,
        25-Hz Sampling Rate
  • Receiver:
    • Supports 3 Time-Multiplexed PD Inputs
    • 24-Bit Representation of Current Input From PD in Two’s-Complement Format
    • Individual DC Offset Subtraction DAC
      (Up to ±127-µA Range) at TIA Input for Each LED, Ambient
    • Digital Ambient Subtraction at ADC Output
    • Transimpedance Gain: 10 kΩ to 2 MΩ
    • Noise Filtering With Programmable Bandwidth
    • Receiver Operates at Approximately 1-µA/Hz Sampling Rate (Example, 25 µA at 25 Hz)
    • Hardware Power-Down Mode: Approximately 0-µA Current
  • Flexible Pulse Sequencing and Timing Control
  • Clocking Via External Clock or Internal Oscillator
  • FIFO With 128-Sample Depth:
    • Programmable Partitioning Across Phases
  • Pin-Selectable I2C, SPI Interface
  • Operating Temperature Range: –20°C to +70°C
  • 2.6-mm × 2.1-mm, 0.4-mm Pitch DSBGA Package
  • Supplies:
    • Tx: 3 V to 5.25 V
    • Rx: 1.8 V to 1.9 V (LDO Bypass),
      2.0 V to 3.6 V (LDO Enabled)
    • IO: 1.7 V to Rx_SUP
  • Accurate, Continuous Heart-Rate Monitoring:
    • Up to 100-dB Dynamic Range for Accurate Heart-Rate Detection
    • Low Current for Continuous Operation on a Wearable Device With a Typical Value:
      • 30 µA for an LED, 25 µA for the Receiver
  • Transmitter:
    • 4 LEDs in Common Anode Configurations
    • 8-Bit Programmable LED Current to 200 mA
    • Mode to Fire Two LEDs in Parallel
    • Programmable LED On-Time
    • Simultaneous Support of 3 LEDs for Optimized SpO2, HRM, or Multiwavelength HRM
    • Average Current of 30 µA Adequate for a Typical Heart-Rate Monitoring Scenario:
      • 20-mA Setting, 60-µs Pulse Duration,
        25-Hz Sampling Rate
  • Receiver:
    • Supports 3 Time-Multiplexed PD Inputs
    • 24-Bit Representation of Current Input From PD in Two’s-Complement Format
    • Individual DC Offset Subtraction DAC
      (Up to ±127-µA Range) at TIA Input for Each LED, Ambient
    • Digital Ambient Subtraction at ADC Output
    • Transimpedance Gain: 10 kΩ to 2 MΩ
    • Noise Filtering With Programmable Bandwidth
    • Receiver Operates at Approximately 1-µA/Hz Sampling Rate (Example, 25 µA at 25 Hz)
    • Hardware Power-Down Mode: Approximately 0-µA Current
  • Flexible Pulse Sequencing and Timing Control
  • Clocking Via External Clock or Internal Oscillator
  • FIFO With 128-Sample Depth:
    • Programmable Partitioning Across Phases
  • Pin-Selectable I2C, SPI Interface
  • Operating Temperature Range: –20°C to +70°C
  • 2.6-mm × 2.1-mm, 0.4-mm Pitch DSBGA Package
  • Supplies:
    • Tx: 3 V to 5.25 V
    • Rx: 1.8 V to 1.9 V (LDO Bypass),
      2.0 V to 3.6 V (LDO Enabled)
    • IO: 1.7 V to Rx_SUP

TheAFE4410is an analog front-end for optical biosensing applications, such as heart rate monitoring (HRM). The device supports a maximum of four switching light-emitting diodes (LEDs) and a maximum of three photodiodes (PDs). The electrical current from the photodiode is converted into voltage by the transimpedance amplifier (TIA) and digitized using an analog-to-digital converter (ADC). The ADC code is stored in a 128-sample first-in, first-out block (FIFO) with programmable depth. The FIFO can be read out using either an I2C interface or a serial peripheral interface (SPI). The AFE also has a fully integrated LED driver with 8-bit current control. The device has high dynamic range transmit-and-receive circuitry offering a dynamic range of up to 100 dB that enables accurate heart ratesensing. The AFE achieves extremely low current levels by operating an ultralow power (ULP) mode set by using the ENABLE_ULP register bit.


TheAFE4410is an analog front-end for optical biosensing applications, such as heart rate monitoring (HRM). The device supports a maximum of four switching light-emitting diodes (LEDs) and a maximum of three photodiodes (PDs). The electrical current from the photodiode is converted into voltage by the transimpedance amplifier (TIA) and digitized using an analog-to-digital converter (ADC). The ADC code is stored in a 128-sample first-in, first-out block (FIFO) with programmable depth. The FIFO can be read out using either an I2C interface or a serial peripheral interface (SPI). The AFE also has a fully integrated LED driver with 8-bit current control. The device has high dynamic range transmit-and-receive circuitry offering a dynamic range of up to 100 dB that enables accurate heart ratesensing. The AFE achieves extremely low current levels by operating an ultralow power (ULP) mode set by using the ENABLE_ULP register bit.


下載 觀看有字幕稿的影片 影片

更多資訊

根據 NDA 提供完整的產品規格表和其他設計資源。立即索取

您可能會感興趣的類似產品

open-in-new 比較替代產品
功能相同,但引腳輸出與所比較的產品不同
AFE44I30 現行 適用具 FIFO 和 I2C 之穿戴式光學生物感測的超低功耗整合式類比前端 (AFE) Higher SNR, 6 LEDs, 4 PDs, and improved automatic ambient and LED cancellation.
AFE44S30 現行 具 FIFO 和 SPI 且適用穿戴式光學生物感測的超低功耗整合式類比前端 (AFE) Higher SNR, 8 LEDs, 4 PDs, and improved automatic ambient and LED cancellation.

技術文件

star =TI 所選的此產品重要文件
找不到結果。請清除您的搜尋條件,然後再試一次。
檢視所有 2
類型 標題 日期
* Data sheet AFE4410 Ultra-Small, Integrated AFE With FIFO for Wearable, Continuous Optical Heart-Rate Monitoring and Biosensing datasheet (Rev. B) PDF | HTML 2019年 7月 31日
Technical article Optical heart-rate sensors for biometric wearables PDF | HTML 2018年 5月 3日

設計與開發

如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。

開發板

AFE4403EVM — 適用於心率監控器和脈搏血氧儀的 AFE4403 整合式 AFE 評估模組

The AFE4403EVM is intended for evaluating the AFE4403 device. The fully integrated AFE is ideally suited for Pulse Oximeter and Heart rate monitoring applications and consists of low noise receive channel, the LED transmit section and diagnostics for sensor and LED fault detection. The AFE4403 has (...)

使用指南: PDF
TI.com 無法提供
開發板

AFE4410EVM — 具有 FIFO 且適用於穿戴式光學心率監測的 AFE4410 整合式 AFE 評估模組

The AFE4410 is an analog front end (AFE) for optical biosensing applications, such as heart-rate monitoring (HRM) and saturation of peripheral capillary oxygen (SpO2). The device supports four switching light-emitting diodes (LEDs) and three photodiodes. The current from the photodiode is converted (...)

開發板

AFE4490SPO2EVM — 適用於脈搏血氧儀的 AFE4490 整合式類比前端 (AFE) 評估模組

The AFE44x0SPO2EVM is intended for evaluating AFE4400 and AFE4490 devices. The family of devices are fully integrated AFE ideally suited for Pulse Oximeter applications and consist of low noise receive channel, the LED transmit section and diagnostics for sensor and LED fault detection. The (...)

使用指南: PDF
TI.com 無法提供
模擬工具

PSPICE-FOR-TI — PSpice® for TI 設計與模擬工具

PSpice® for TI is a design and simulation environment that helps evaluate functionality of analog circuits. This full-featured, design and simulation suite uses an analog analysis engine from Cadence®. Available at no cost, PSpice for TI includes one of the largest model libraries in the (...)
封裝 引腳 下載
DSBGA (YZ) 30 檢視選項

訂購與品質

內含資訊:
  • RoHS
  • REACH
  • 產品標記
  • 鉛塗層/球物料
  • MSL 等級/回焊峰值
  • MTBF/FIT 估算值
  • 材料內容
  • 資格摘要
  • 進行中可靠性監測
內含資訊:
  • 晶圓廠位置
  • 組裝地點

建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。

支援與培訓

內含 TI 工程師技術支援的 TI E2E™ 論壇

內容係由 TI 和社群貢獻者依「現狀」提供,且不構成 TI 規範。檢視使用條款

若有關於品質、封裝或訂購 TI 產品的問題,請參閱 TI 支援。​​​​​​​​​​​​​​

影片