Over operating free-air temperature range (unless otherwise
noted)(1)
|
MIN |
MAX |
UNIT |
| Supply
voltage |
VDD –
VSS |
–0.3 |
30 |
V |
| Input voltage |
V4 – V3, V3 –
V2, V2 – V1, V1 – VSS |
–0.3 |
30 |
| REG –
VSS |
–0.3 |
3.6 |
| Output
voltage |
OUT –
VSS |
–0.3 |
30 |
| Continuous total power dissipation, PTOT |
See
Section 6.4. |
|
| Lead
temperature (soldering, 10 s), TSOLDER |
300 |
300 |
°C |
| Storage temperature, Tstg |
–65 |
150 |
°C |
(1) Operation outside the Absolute Maximum Ratings may cause
permanent device damage. Absolute Maximum Ratings do not imply functional operation of the
device at these or any other conditions beyond those listed under Recommended Operating
Conditions. If outside the Recommended Operating Conditions but within the Absolute
Maximum Ratings, the device may not be fully functional, and this may affect device
reliability, functionality, performance, and shorten the device lifetime.