SLUSFB5A June 2024 – April 2025 BQ41Z50
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
|---|---|---|---|---|---|---|
| VIN | Input voltage range | TS1, TS2, TS3, TS4, VBIAS = VREG18 | –0.2 | VREG18 | V | |
| RTS_PU | Internal pull-up resistance | TS1, TS2, TS3, Setting for nominal 18kΩ | 14.4 | 18 | 21.6 | kΩ |
| RTS4_PU (2) | Internal pull-up resistance for TS4 | TS4 | 17 | 18 | 19 | kΩ |
| RTSx_PU_DRIFT(1) | Internal pull-up resistance change over temperature | Change over –40°C to +85°C vs value at 25°C for nominal 18kΩ | –200 | 200 | Ω | |