SNAS693C July   2017  – May 2019 HDC2010

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
    1.     Device Images
      1.      Typical Application
      2.      RH Accuracy
  4. Revision History
  5. Pin Configuration and Functions
    1.     Pin Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 I2C Interface Electrical Characteristics
    7. 6.7 I2C Interface Timing Requirements
    8. 6.8 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Sleep Mode Power Consumption
      2. 7.3.2 Measurement Modes: Trigger on Demand vs. Auto Measurement
      3. 7.3.3 Heater
      4. 7.3.4 Interrupt Description
        1. 7.3.4.1 DRDY
      5. 7.3.5 INTERRUPT on Threshold
        1. 7.3.5.1 Temperature High
        2. 7.3.5.2 Temperature Low
        3. 7.3.5.3 Humidity High
        4. 7.3.5.4 Humidity Low
    4. 7.4 Device Functional Modes
      1. 7.4.1 Sleep Mode vs. Measurement Mode
    5. 7.5 Programming
      1. 7.5.1 I2C Serial Bus Address Configuration
      2. 7.5.2 I2C Interface
      3. 7.5.3 Serial Bus Address
      4. 7.5.4 Read and Write Operations
    6. 7.6 Register Maps
      1. 7.6.1  Address 0x00 Temperature LSB
        1. Table 1. Address 0x00 Temperature LSB Register
        2. Table 7. Address 0x00 Temperature LSB Field Descriptions
      2. 7.6.2  Address 0x01 Temperature MSB
        1. Table 2. Address 0x01 Temperature MSB Register
        2. Table 8. Address 0x01 Temperature MSB Field Descriptions
      3. 7.6.3  Address 0x02 Humidity LSB
        1. Table 3. Address 0x02 Humidity LSB Register
        2. Table 9. Address 0x02 Humidity LSB Field Descriptions
      4. 7.6.4  Address 0x03 Humidity MSB
        1. Table 4.  Address 0x03 Humidity MSB Register
        2. Table 10. Address 0x03 Temperature MSB Field Descriptions
      5. 7.6.5  Address 0x04 Interrupt DRDY
        1. Table 5.  Address 0x04 Interrupt DRDY Register
        2. Table 11. Address 0x04 Interrupt DRDY Field Descriptions
      6. 7.6.6  Address 0x05 Temperature MAX
        1. Table 6.  Address 0x05 Temperature MAX Register
        2. Table 12. Address 0x05 Temperature Max Field Descriptions
      7. 7.6.7  Address 0x06 Humidity MAX
        1. Table 7.  Address 0x06 Humidity MAX Register
        2. Table 13. Address 0x06 Humidity MAX Field Descriptions
      8. 7.6.8  Address 0x07 Interrupt Configuration
        1. Table 8.  Address 0x07 Interrupt Configuration Register
        2. Table 14. Address 0x07 Interrupt Configuration Field Descriptions
      9. 7.6.9  Address 0x08 Temperature Offset Adjustment
        1. Table 9.  Address 0x08 Temperature Offset Adjustment Register
        2. Table 15. Address 0x08 Temperature Offset Adjustment Field Descriptions
      10. 7.6.10 Address 0x09 Humidity Offset Adjustment
        1. Table 10. Address 0x09 Humidity Offset Adjustment Register
        2. Table 16. Address 0x09 Humidity Offset Adjustment Field Descriptions
      11. 7.6.11 Address 0x0A Temperature Threshold LOW
        1. Table 11. Address 0x0A Temperature Threshold LOW Register
        2. Table 17. Address 0x0A Temperature Threshold LOW Field Descriptions
      12. 7.6.12 Address 0x0B Temperature Threshold HIGH
        1. Table 12. Address 0x0B Temperature Threshold HIGH Register
        2. Table 18. Address 0x0B Temperature Threshold HIGH Field Descriptions
      13. 7.6.13 Address 0x0C Humidity Threshold LOW
        1. Table 13. Address 0x0C Humidity Threshold LOW Register
        2. Table 19. Address 0x0C Humidity Threshold LOW Field Descriptions
      14. 7.6.14 Address 0x0D Humidity Threshold HIGH
        1. Table 14. Address 0x0D Humidity Threshold HIGH Register
        2. Table 20. Address 0x0D Humidity Threshold HIGH Field Descriptions
      15. 7.6.15 Address 0x0E Reset and DRDY/INT Configuration Register
        1. Table 15. Address 0x0E Configuration Register
        2. Table 21. Address 0x0E Configuration Field Descriptions
      16. 7.6.16 Address 0x0F Measurement Configuration
        1. Table 16. Address 0x0F Measurement Configuration Register
        2. Table 22. Address 0x0F Measurement Configuration Field Descriptions
      17. 7.6.17 Manufacturer ID Low
        1. Table 17. Manufacturer ID Low Register
        2. Table 23. Address 0xFC Manufacturer ID Low Field Descriptions
      18. 7.6.18 Manufacturer ID High
        1. Table 18. Manufacturer ID High Register
        2. Table 24. Address 0xFD Manufacturer ID High Field Descriptions
      19. 7.6.19 Device ID Low
        1. Table 19. Device ID Low Register
        2. Table 25. Address 0xFE Device ID Low Field Descriptions
      20. 7.6.20 Device ID High
        1. Table 20. Device ID High Register
        2. Table 26. Address 0xFF Device ID High Field Descriptions
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curve
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
      1. 10.1.1 Guidelines for HDC2010 Storage and PCB Assembly
        1. 10.1.1.1 Storage and Handling
        2. 10.1.1.2 Soldering Reflow
        3. 10.1.1.3 Rework
        4. 10.1.1.4 High Temperature and Humidity Exposure
        5. 10.1.1.5 Bake/Re-Hydration Procedure
    2. 10.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 Documentation Support
      1. 11.1.1 Related Documentation
    2. 11.2 Receiving Notification of Documentation Updates
    3. 11.3 Community Resources
    4. 11.4 Trademarks
    5. 11.5 Electrostatic Discharge Caution
    6. 11.6 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Features

  • Relative humidity range: 0% to 100%
  • Humidity accuracy: ±2%
  • Sleep current: 50 nA
  • Average supply current (1 measurement per second)
    • RH only (11 bit): 300 nA
    • RH (11 bit) + temperature (11 bit): 550 nA
  • Temperature range:
    • Operating: –40°C to 85°C
    • Functional: –40°C to 125°C
  • Temperature accuracy: ±0.2°C typical
  • Supply voltage: 1.62 V to 3.6 V
  • Programmable sampling rate (5 Hz, 2 Hz, 1 Hz, 0.2 Hz, 0.1 Hz, 1/60 Hz, 1/120 Hz) or trigger on demand
  • I2C interface