SNAS693D July   2017  – February 2021 HDC2010

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Pin Configuration and Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 I2C Interface Timing Requirements
    7. 6.7 I2C Interface Electrical Characteristics
    8. 6.8 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Sleep Mode Power Consumption
      2. 7.3.2 Measurement Modes: Trigger on Demand vs. Auto Measurement
      3. 7.3.3 Heater
      4. 7.3.4 Interrupt Description
        1. 7.3.4.1 DRDY
      5. 7.3.5 INTERRUPT on Threshold
        1. 7.3.5.1 Temperature High
        2. 7.3.5.2 Temperature Low
        3. 7.3.5.3 Humidity High
        4. 7.3.5.4 Humidity Low
    4. 7.4 Device Functional Modes
      1. 7.4.1 Sleep Mode vs. Measurement Mode
    5. 7.5 Programming
      1. 7.5.1 I2C Serial Bus Address Configuration
      2. 7.5.2 I2C Interface
      3. 7.5.3 Serial Bus Address
      4. 7.5.4 Read and Write Operations
    6. 7.6 Register Maps
      1. 7.6.1  Address 0x00 Temperature LSB
      2. 7.6.2  Address 0x01 Temperature MSB
      3. 7.6.3  Address 0x02 Humidity LSB
      4. 7.6.4  Address 0x03 Humidity MSB
      5. 7.6.5  Address 0x04 Interrupt DRDY
      6. 7.6.6  Address 0x05 Temperature MAX
      7. 7.6.7  Address 0x06 Humidity MAX
      8. 7.6.8  Address 0x07 Interrupt Configuration
      9. 7.6.9  Address 0x08 Temperature Offset Adjustment
      10. 7.6.10 46
      11. 7.6.11 Address 0x09 Humidity Offset Adjustment
      12. 7.6.12 48
      13. 7.6.13 Address 0x0A Temperature Threshold LOW
      14. 7.6.14 Address 0x0B Temperature Threshold HIGH
      15. 7.6.15 Address 0x0C Humidity Threshold LOW
      16. 7.6.16 Address 0x0D Humidity Threshold HIGH
      17. 7.6.17 Address 0x0E Reset and DRDY/INT Configuration Register
      18. 7.6.18 Address 0x0F Measurement Configuration
      19. 7.6.19 Manufacturer ID Low
      20. 7.6.20 Manufacturer ID High
      21. 7.6.21 Device ID Low
      22. 7.6.22 Device ID High
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curve
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
      1. 10.1.1 Guidelines for HDC2010 Storage and PCB Assembly
        1. 10.1.1.1 Storage and Handling
        2. 10.1.1.2 Soldering Reflow
        3. 10.1.1.3 Rework
        4. 10.1.1.4 High Temperature and Humidity Exposure
        5. 10.1.1.5 Bake/Re-Hydration Procedure
    2. 10.2 Layout Example
  11. 11Device and Documentation Support
    1. 11.1 Documentation Support
      1. 11.1.1 Related Documentation
    2. 11.2 Receiving Notification of Documentation Updates
    3. 11.3 Support Resources
    4. 11.4 Trademarks
    5. 11.5 Electrostatic Discharge Caution
    6. 11.6 Glossary
  12. 12Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Address 0x07 Interrupt Configuration

Table 7-21 Address 0x07 Interrupt Configuration Register
76543210
DRDY_ENABLETH_ENABLETL_ENABLEHH_ENABLEHL_ENABLERESRESRES
Table 7-22 Address 0x07 Interrupt Configuration Field Descriptions
BITFIELDTYPERESETDESCRIPTION
7DRDY_ENABLER/W0DataReady Interrupt enable
0 = DataReady Interrupt generator disable
1 = DataReady Interrupt generator enable
6TH_ENABLER/W0Temperature threshold HIGH Interrupt enable
0 = Temperature high Interrupt generator disable
1 = Temperature high Interrupt generator enable
5TL_ENABLER/W0Temperature threshold LOW Interrupt enable
0 = Temperature low Interrupt generator disable
1 = Temperature low Interrupt generator enable
4HH_ENABLER/W0Humidity threshold HIGH Interrupt enable
0 = Humidity high Interrupt generator disable
1 = Humidity high Interrupt generator enable
3HL_ENABLER/W0Humidity threshold LOW Interrupt enable
0 = Humidity low Interrupt generator disable
1 = Humidity low Interrupt generator enable
2RES0Reserved
1RES0Reserved
0RES0Reserved