SLLSEU0C November   2016  – February 2020 ISO7740-Q1 , ISO7741-Q1 , ISO7742-Q1

PRODUCTION DATA.  

  1. Features
  2. Applications
  3. Description
    1.     Simplified Schematic
  4. Revision History
  5. Description Continued
  6. Pin Configuration and Functions
    1.     Pin Functions
  7. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  Recommended Operating Conditions
    4. 7.4  Thermal Information
    5. 7.5  Power Rating
    6. 7.6  Insulation Specifications
    7. 7.7  Safety-Related Certifications
    8. 7.8  Safety Limiting Values
    9. 7.9  Electrical Characteristics—5-V Supply
    10. 7.10 Supply Current Characteristics—5-V Supply
    11. 7.11 Electrical Characteristics—3.3-V Supply
    12. 7.12 Supply Current Characteristics—3.3-V Supply
    13. 7.13 Electrical Characteristics—2.5-V Supply
    14. 7.14 Supply Current Characteristics—2.5-V Supply
    15. 7.15 Switching Characteristics—5-V Supply
    16. 7.16 Switching Characteristics—3.3-V Supply
    17. 7.17 Switching Characteristics—2.5-V Supply
    18. 7.18 Insulation Characteristics Curves
    19. 7.19 Typical Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1 Electromagnetic Compatibility (EMC) Considerations
    4. 9.4 Device Functional Modes
      1. 9.4.1 Device I/O Schematics
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
      3. 10.2.3 Application Curve
        1. 10.2.3.1 Insulation Lifetime
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
      1. 12.1.1 PCB Material
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Documentation Support
      1. 13.1.1 Related Documentation
    2. 13.2 Related Links
    3. 13.3 Receiving Notification of Documentation Updates
    4. 13.4 Community Resources
    5. 13.5 Trademarks
    6. 13.6 Electrostatic Discharge Caution
    7. 13.7 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • DBQ|16
  • DWW|16
  • DW|16
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Safety-Related Certifications

VDE CSA UL CQC TUV
Certified according to DIN VDE V 0884-11:2017-01 Certified according to IEC 60950-1, IEC 62368-1 and IEC 60601-1 Certified according to UL 1577 Component Recognition Program Certified according to GB 4943.1-2011 Certified according to EN 61010-1:2010/A1:2019, EN 60950-1:2006/A2:2013 and EN 62368-1:2014
Maximum transient isolation voltage, 8000 VPK (DWW-16, DW-16) and 4242 VPK (DBQ-16);
Maximum repetitive peak isolation voltage, 2828 VPK (DWW-16, Reinforced), 2121 VPK (DW-16, Reinforced) and 566 VPK (DBQ-16);
Maximum surge isolation voltage, 8000 VPK (DWW-16, DW-16) and 4000 VPK (DBQ-16)
Reinforced insulation per CSA 60950-1-07+A1+A2, IEC 60950-1 2nd Ed.+A1+A2, CSA 62368-1-14 and IEC 62368-1 2nd Ed.
1450 VRMS (DWW-16), 800 VRMS (DW-16) and 370 VRMS (DBQ-16) max working voltage (pollution degree 2, material group I);
2 MOPP (Means of Patient Protection) per CSA 60601-1:14 and IEC 60601-1 Ed. 3.1, 400 VRMS (DWW-16) and 250 VRMS (DW-16) max working voltage
DW-16: Single protection, 5000 VRMS;
DBQ-16: Single protection, 3000 VRMS
DWW-16: Reinforced Insulation, Altitude ≤ 5000 m, Tropical Climate, 1450 VRMS maximum working voltage;
DW-16: Reinforced Insulation, Altitude ≤ 5000 m, Tropical Climate, 700 VRMS maximum working voltage;
DBQ-16: Basic Insulation, Altitude ≤ 5000 m, Tropical Climate, 400 VRMS maximum working voltage
5700 VRMS (DWW-16), 5000 VRMS (DW-16) and 3000 VRMS (DBQ-16) Reinforced insulation per EN 61010-1:2010/A1:2019 up to working voltage of 1000 VRMS (DWW-16), 600 VRMS (DW-16) and 300 VRMS (DBQ-16)
5700 VRMS (DWW-16), 5000 VRMS (DW-16) and 3000 VRMS (DBQ-16) Reinforced insulation per EN 60950-1:2006/A2:2013 and EN 62368-1:2014 up to working voltage of 1450 VRMS (DWW-16), 800 VRMS (DW-16) and 370 VRMS (DBQ-16)
Certificate number: 40040142 Master contract number: 220991 File number: E181974 Certificate numbers:
CQC15001121716 (DWx-16)
CQC18001199097 (DBQ-16)
Client ID number: 77311