SNVS411D January 2006 – December 2025 LM25005
PRODUCTION DATA
An example of the step-by-step procedure to generate power stage and compensation component values using the typical application setup of Figure 6-1 is given below. The circuit shown in Figure 6-1 is configured for the following specifications:
| PARAMETER | VALUE |
|---|---|
| Input Voltage | 7V to 42V |
| Output Voltage | 5V |
| Minimum load current (for CCM) | 250mA |
| Maximum load current | 2.5A |
| Switching Frequency | 300kHz |