6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)(1) | MIN | NOM | MAX | UNIT |
| VIN |
Input voltage |
VIN |
3.8 |
| 42 |
V |
| SW to PGND |
–0.3 |
| 42 |
V |
| HB to SW |
–0.3 |
5 |
5.25 |
V |
| HO, HOL to SW |
–0.3 |
| HB + 0.3 |
V |
| LO, LOL to PGND |
–0.3 |
5 |
5.25 |
V |
| FB, PG, OSC, SS, RES, DEMB, VCCX |
–0.3 |
| 5 |
V |
| EN to PGND |
–0.3 |
| 42 |
V |
| VCC, VDD |
–0.3 |
5 |
5.25 |
V |
| VOUT, CS |
1.5 |
5 |
15 |
V |
| PGND to AGND |
–0.3 |
| 0.3 |
V |
| Operating junction temperature(2) |
–40 |
| 125 |
°C |
(1) Recommended Operating Conditions are conditions under which the device is intended to be functional. For specifications and test conditions, see
Electrical Characteristics.
(2) High junction temperatures degrade operating lifetimes. Operating lifetime is de-rated for junction temperatures greater than 125°C.