SBOS301C May 2004 – December 2025 LOG114
PRODUCTION DATA
The LOG114 uses two matched logarithmic amplifiers (A1 and A2 with logging diodes in the feedback loops) to generate the outputs log (I1) and log (I2), respectively. The gain of 6.25 differential amplifier (A3) subtracts the output of A2 from the output of A1, resulting in [log(I1) − log(I2)], or log(I1/I2). The symmetrical design of the A1 and A2 logarithmic amps allows I1 and I2 to be used interchangeably, and provides good bandwidth and phase characteristics with frequency.