SBOS258E November 2002 – April 2025 OPA698
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
Capacitive loads, such as the input to ADCs, decreases the amplifier phase margin, which can cause high-frequency peaking or oscillations. Figure 8-3 shows how capacitive loads ≥ 2pF can be isolated by connecting a small resistor in series with the output. Increasing the gain from 2V/V improves the capacitive drive capabilities as a result of increased phase margin.
Figure 8-3 Driving Capacitive
LoadsIn general, minimize capacitive loads for optimized high-frequency performance. The capacitance of coax cable (29pF/ft for RG-58) cannot load the amplifier when the coaxial cable, or transmission line, is terminated in the characteristic impedance.