SBVS058D June   2005  – April 2026 REF3212 , REF3220 , REF3225 , REF3230 , REF3233 , REF3240

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Pin Configuration and Functions
  6. 5 Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Electrical Characteristics
    4. 5.4 Typical Characteristics
  7. 6 Detailed Description
    1. 6.1 Overview
      1. 6.1.1 Supply Voltage
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Thermal Hysteresis
      2. 6.3.2 Temperature Drift
      3. 6.3.3 Noise Performance
      4. 6.3.4 Load Regulation
    4. 6.4 Device Functional Modes
      1. 6.4.1 Shutdown
  8. 7 Application and Implementation
    1. 7.1 Application Information
      1. 7.1.1 Long-Term Stability
    2. 7.2 Typical Application
      1. 7.2.1 Detailed Design Procedure
        1. 7.2.1.1 Negative Reference Voltage
        2. 7.2.1.2 Data Acquisition
  9. 8 Device and Documentation Support
    1. 8.1 Receiving Notification of Documentation Updates
    2. 8.2 Support Resources
    3. 8.3 Trademarks
    4. 8.4 Electrostatic Discharge Caution
    5. 8.5 Glossary
  10. 9 Revision History
  11. 10Mechanical, Packaging, and Orderable Information

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Data Acquisition

Data acquisition systems often require stable voltage references to maintain accuracy. The REF32xx family features stability and a wide range of voltages suitable for most microcontrollers and data converters. Figure 7-3, Figure 7-4, and Figure 7-5 show basic data acquisition systems.

REF3212 REF3220 REF3225 REF3230 REF3233 REF3240 REF3225 Combined with OPA735 to Create Positive and Negative Reference Voltages
Bypass capacitor is not shown.
Figure 7-2 REF3225 Combined with OPA735 to Create Positive and Negative Reference Voltages
REF3212 REF3220 REF3225 REF3230 REF3233 REF3240 Basic Data Acquisition System 1Figure 7-3 Basic Data Acquisition System 1
REF3212 REF3220 REF3225 REF3230 REF3233 REF3240 Basic Data Acquisition System 2Figure 7-4 Basic Data Acquisition System 2
REF3212 REF3220 REF3225 REF3230 REF3233 REF3240 REF3240 Provides an Accurate Reference for Driving the ADS8381Figure 7-5 REF3240 Provides an Accurate Reference for Driving the ADS8381