over operating free-air temperature range (unless otherwise
noted)(1)
|
|
MIN |
MAX |
UNIT |
| VCC (see (2)) |
Supply voltage range |
|
−0.3 |
6 |
V |
|
Voltage range at any bus
input (steady state) |
A and B |
−10 |
15 |
V |
|
Voltage range at any bus
input |
transient pulse through 100
Ω, see Figure 6-5 |
−30 |
30 |
V |
| VI
|
Voltage input range at 1,2EN
and 3,4EN |
|
−0.5 |
VCC + 0.5 |
V |
| IO
|
Receiver output
current |
|
±10 |
mA |
|
|
Electrostatic
discharge: |
|
|
|
|
|
Continuous power
dissipation |
|
See Power
Dissipation Rating Table |
|
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential I/O bus voltages, are with respect to GND, and are steady-state (unless otherwise specified).