SLVSKV5 November 2026 TAS2785
PRODUCTION DATA
The TAS2785 Class-D amplifier supports spread spectrum PWM modulation, which can be enabled by setting the AMP_SS register bit high. This can help reduce EMI in the system.
By default the Class-D amplifier switching frequency is based on the device trimmed internal oscillator. To synchronize switching to the audio sample rate, set the CLASSD_SYNC register bit high. When the Class-D is synchronized to the audio sample rate, the RAMP_RATE register bit must be set depending on the audio sample rate of either 44.1kHz or 48kHz (default) based frequency.