Table 9-1 shows the intended operating parameters for this application example. Also included is the total Y-rated filter capacitance that is allowed in order to meet the applicable touch current fault specification.
| DESIGN PARAMETER | VALUE |
|---|---|
| AC input voltage | 230 V L-N or 400 V L-L (RMS) |
| AC input line frequency | 47 Hz to 63 Hz |
| DC output voltage range | 600 V to 1 kV |
| DC output current (max) | 18 A |
| Rated output power | 10 kW |
| AC/DC stage switching frequency | 100 kHz |
| Total Y-rated filter capacitance (maximum) | 10 nF |