JAJSP96E April   2005  – October 2022 MAX3243E

PRODUCTION DATA  

  1. 特長
  2. アプリケーション
  3. 概要
  4. Revision History
  5. 概要 (続き)
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  ESD Ratings - IEC Specifications
    4. 7.4  Recommended Operating Conditions
    5. 7.5  Thermal Information
    6. 7.6  Electrical Characteristics
    7. 7.7  Driver Electrical Characteristics
    8. 7.8  Receiver, Electrical Characteristics
    9. 7.9  Auto-Powerdown Electrical Characteristics
    10. 7.10 Driver Switching Characteristics
    11. 7.11 Receiver Switching Characteristics
    12. 7.12 Auto-Powerdown Switching Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
    4. 9.4 Device Functional Modes
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
      2. 10.2.2 Detailed Design Procedure
        1. 10.2.2.1 ESD Protection
          1. 10.2.2.1.1 ESD Test Conditions
          2. 10.2.2.1.2 Human Body Model (HBM)
          3. 10.2.2.1.3 IEC61000-4-2 (Formerly Known as IEC1000-4-2)
          4. 10.2.2.1.4 Machine Model
    3. 10.3 Power Supply Recommendations
    4. 10.4 Layout
      1. 10.4.1 Layout Example
        1.       Device and Documentation Support
          1. 11.1 Receiving Notification of Documentation Updates
          2. 11.2 サポート・リソース
          3. 11.3 Trademarks
          4. 11.4 Electrostatic Discharge Caution
          5. 11.5 Glossary
  11. 11Mechanical, Packaging, and Orderable Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

Electrical Characteristics

over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)(1) (see Figure 10-1)
PARAMETERTEST CONDITIONSMINTYP(2)MAXUNIT
IIInput leakage currentFORCEOFF, FORCEON±0.01±1μA
ICCSupply current
(TA = 25°C)
Auto-powerdown disabledNo load,
FORCEOFF and FORCEON at VCC
For DB, PW and RHB package
0.31.2mA
Auto-powerdown disabled No load,
FORCEOFF and FORCEON at VCC
For DW package
0.3 1 mA
Powered offNo load, FORCEOFF at GND110μA
Auto-powerdown enabledNo load, FORCEOFF at VCC,
FORCEON at GND,
All RIN are open or grounded,
All DIN are grounded
110
Test conditions are C1–C4 = 0.1 μF at VCC = 3.3 V ± 0.3 V; C1 = 0.047 μF, C2–C4 = 0.33 μF at VCC = 5 V ± 0.5 V.
All typical values are at VCC = 3.3 V or VCC = 5 V, and TA = 25°C.