JAJSM70A June 2021 – November 2021 TAS6424E-Q1
PRODUCTION DATA
デバイスごとのパッケージ図は、PDF版データシートをご参照ください。
The AC Load Diagnostic Control 1 register is shown in Figure 9-32 and described in Table 9-28.
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
CH1 GAIN | CH2 GAIN | CH3 GAIN | CH4 GAIN | CH1 ENABLE | CH2 ENABLE | CH3 ENABLE | CH4 ENABLE |
R/W-0 | R/W-0 | R/W-0 | R/W-0 | R/W-0 | R/W-0 | R/W-0 | R/W-0 |
Bit | Field | Type | Reset | Description |
---|---|---|---|---|
7 | CH1, PBTL12: GAIN | R/W | 0 | 0: Gain 1 1: Gain 4 |
6 | CH2 GAIN | R/W | 0 | 0: Gain 1 1: Gain 4 |
5 | CH3, CH4, PBTL34: GAIN | R/W | 0 | 0: Gain 1 1: Gain 4 |
4 | CH4 GAIN | R/W | 0 | 0: Gain 1 1: Gain 4 |
3 | CH1 ENABLE | R/W | 0 | 0: AC diagnostics disabled 1: Enable AC diagnostics |
2 | CH2 ENABLE | R/W | 0 | 0: AC diagnostics disabled 1: Enable AC diagnostics |
1 | CH3 ENABLE | R/W | 0 | 0: AC diagnostics disabled 1: Enable AC diagnostics |
0 | CH4 ENABLE | R/W | 0 | 0: AC diagnostics disabled 1: Enable AC diagnostics |