6.1 Absolute Maximum Ratings
over operating temperature range (unless otherwise noted)(1)
|
MIN |
MAX |
UNIT |
| Power supply, V+ |
–0.3 |
6 |
V |
| Input voltage |
THERM, ALERT/THERM2, SDA and SCL only |
–0.3 |
6 |
V |
| D+, A0, A1 |
–0.3 |
(V+) + 0.3 |
| D– only |
–0.3 |
0.3 |
| Input current |
|
10 |
mA |
| Operating temperature |
–55 |
150 |
°C |
| Junction temperature, TJ max |
|
150 |
°C |
| Storage temperature, Tstg |
–60 |
150 |
°C |
(1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied.