JAJSL78D september 2009 – may 2021 BQ24050 , BQ24052
PRODUCTION DATA
For host monitoring, a pullup resistor is used between the STATUS pin and the VCC of the host and for a visual indication a resistor in series with an LED is connected between the STATUS pin and a power source. If the CHG source can exceed 7 V, a 6.2-V Zener diode should be used to clamp the voltage. If the source is the OUT pin, note that as the battery changes voltage, the brightness of the LEDs vary.
| CHARGING STATE | CHG FET/LED |
|---|---|
| 1st Charge | ON |
| Refresh Charge | OFF |
| OVP | |
| SLEEP | |
| TEMP FAULT | ON for 1st Charge |