SCLK034 December   2023 SN54SC2T74-SEP

PRODUCTION DATA  

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Bias Diagram
    4. 2.4 Test Configuration and Condition
  6. 3TID Characterization Test Results
    1. 3.1 TID Characterization Summary Results
    2. 3.2 Specification Compliance Matrix
  7. 4Reference Documents
  8. 5Appendix: HDR TID Report Data

Device Details

Table 1-1 lists the device information used for TID HDR characterization and qualification.

Table 1-1 Device and Exposure Details
TID HDR Details: up to 50 krad(Si)
TI Device NumberSN54SC2T74-SEP
Package14-pin PW (TSSOP)
TechnologyLBC9
Die Lot Number2207753RFB
A/T Lot Number and Date Code3301824ML3 / 33AF40K
Quantity Tested31 irradiated devices + 3 control
Lot Accept or RejectDevices passed 30 krad(Si)
HDR Radiation FacilityTexas Instruments CLAB in Dallas, Texas
HDR Dose Level10 krad(Si), 20 krad(Si), 30 krad(Si), 50 krad(Si)
HDR Dose Rate197.21 -rad(Si)/s ionizing radiation
HDR Radiation SourceGammacell 220 Excel (GC-220E) Co-60
Irradiation TemperatureAmbient, room temperature