SLVAEI5A december   2019  – june 2023 TPS25830-Q1 , TPS25830A-Q1 , TPS25831-Q1 , TPS25840-Q1

 

  1.   1
  2.   TPS25830, TPS25831-Q1, and TPS25840-Q1 Short-to-Battery Application
  3.   Trademarks
  4. 1Introduction
  5. 2Short-to-Battery Conventional Application
    1. 2.1 External FET VBUS/DP_IN/DM-IN Short-to-VBAT Application
      1. 2.1.1 VBUS Short-to-VBAT Application
      2. 2.1.2 DP_IN/DM_IN Short-to-VBAT Application
      3. 2.1.3 VBUS /DP_IN/DP_IN Short-to-VBAT Application Summary
    2. 2.2 Without External FET VOUT/DP_IN/DM-IN Short-to-VBAT Application
      1. 2.2.1 VOUT/CSN Short-to-VBAT Application
      2. 2.2.2 DP_IN/DM_IN Short-to-VBAT Application
      3. 2.2.3 VOUT/DP_IN/DP_IN Short-to-VBAT Application Summary
    3. 2.3 CC1/CC2 Short-to-VBAT Application
  6. 3Short-to-Battery Special Application
    1. 3.1 External FET VBUS/DP_IN/DM-IN Short-to-VBAT Application
      1. 3.1.1 VBUS Short-to-VBAT Application
      2. 3.1.2 DP_IN/DM_IN Short-to-VBAT Application
      3. 3.1.3 VBUS/DP_IN/DM-IN Short-toVBAT Application Summary
    2. 3.2 Without External FET VOUT/DP_IN/DM-IN Short-to-VBAT Application
      1. 3.2.1 VOUT Short-to-VBAT Application
      2. 3.2.2 DP_IN/DM_IN Short-to-VBAT Application
      3. 3.2.3 VOUT /DP_IN/DM-IN Short-to-VBAT Application Summary
  7. 4Short-to-Battery Connect to TVS Application
    1. 4.1 VBUS Short-to-VBAT Connect to TVS Application
    2. 4.2 VOUT Short-to-VBAT Connect to TVS Application
    3. 4.3 DP/DM Short-to-VBAT Connect to TVS Application
    4. 4.4 CC1/CC2 Short-to-VBAT Connect to TVS Application
  8. 5Revision History

DP_IN/DM_IN Short-to-VBAT Application

  • Application 1: Power off the power supply, then short DP_IN/DM_IN to VBAT. Figure 3-16 and Figure 3-17 show the test results.
  • Application 2: Short DP_IN/DM_IN to VBAT, then power on the power supply. Figure 3-18 and Figure 3-19 show the test results.
  • Application 3: Short DP_IN/DM_IN to VBAT, power on the power supply, then enable EN. Figure 3-20 and Figure 3-21 show the test results.
GUID-56FB247D-9146-43FD-B605-035B7733D92D-low.png
CH1 = 5 V/div, CH2 = 5 V/div, CH3 = 5 V/div, 2 µS/div
Figure 3-16 Power Off, DP_IN Short-to-VBAT Test
GUID-A3BAA8BB-3EAE-4E03-8156-F33AEAECE25C-low.png
CH1 = 5 V/div, CH2 = 5 V/div, CH3 = 5 V/div, 10 mS/div
Figure 3-18 DP_IN Short to VBAT, then Power On Test
GUID-0874CAAD-02D0-455A-AB77-DD8A31BD1969-low.png
CH1 = 5 V/div, CH2 = 5 V/div, CH3 = 5 V/div, CH3 = 5 V/div, 400 mS/div
Figure 3-20 DM_IN Short to VBAT and Power On, then Enable On Test
GUID-36E9EBED-39EF-43C9-A9CF-F540B2422F23-low.png
CH1 = 5V/div, CH2 = 5 V/div, CH3 = 5 V/div, 2 µS/div
Figure 3-17 Power Off, DM_IN Short-to-VBAT Test
GUID-9C1F9D59-96C3-40E3-A568-71A0C8BCE903-low.png
CH1 = 5 V/div, CH2 = 5 V/div, CH3 = 5 V/div, 10 mS/div
Figure 3-19 DM_IN Short to VBAT, then Power On Test
GUID-CD4283EE-2414-4EC4-831A-021BD353257B-low.png
CH1 = 5 V/div, CH2 = 5 V/div, CH3 = 5 V/div, CH3 = 5 V/div, 400 mS/div