TIDT304 October   2022

 

  1.   Description
  2.   Features
  3.   Applications
  4. 1Test Prerequisites
    1. 1.1 Voltage and Current Requirements
    2. 1.2 Required Equipment
    3. 1.3 Test Setup
  5. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Efficiency Data
    3. 2.3 Thermal Images
  6. 3Waveforms
    1. 3.1 Steady State
    2. 3.2 Switching
    3. 3.3 Load Transients

Load Transients

The load transients waveforms were captured at 220 VAC with slew rate = 1 A/μs, CH1: Input current, CH3: Output voltage.

GUID-20220906-SS0I-ZM97-B7JB-X8FLRHCV3FHS-low.png Figure 3-6 220 VAC, 50% Load to 100% Load Transient
GUID-20220906-SS0I-HJ76-L9NL-L9TNG84KK7T6-low.png Figure 3-7 220 VAC, 100% Load to 50% Load Transient
GUID-20220906-SS0I-SDKK-HLMM-SWNRF3P1CDHN-low.png Figure 3-8 220 VAC, 0% Load to 50% Load Transient
GUID-20220906-SS0I-TCDD-HPR5-CWZSMDLFL0RM-low.png Figure 3-9 220 VAC, 50% Load to 0% Load Transient