The
DLP390TP DMD connects
to a PCB or a flex circuit using an interposer.
For additional layout guidelines regarding length
matching and impedance, see the DLPC8445V controller
data sheet. For a detailed layout example, refer
to the layout design files. Some layout guidelines
for routing to the DLP390TP DMD are:
- Match lengths for the LS_WDATA
and LS_CLK signals, as specified in the DLPC8445V controller
data sheet.
- Match lengths for the HS_bus differential signals
as specified in the DLPC8445V controller data sheet.
- Minimize vias, layer changes, and turns for the
HS bus signals.
- Supply capacitance needs can vary per design.
Refer to the layout design file for a general
guideline. Verify all supplies on the design are
operating in the recommended operating range at
the DMD.