During power-up, VDD
and VDDI must always start and settle before VOFFSET plus
Delay1, VBIAS, and VRESET voltages are applied to the
DMD.
During power-up, it is a strict
requirement that the voltage difference between VBIAS and
VOFFSET must be within the specified limit shown in Section 5.4.
During power-up, there is no
requirement for the relative timing of VRESET with respect to
VBIAS.
Power supply slew rates during
power-up are flexible, provided that the transient voltage levels follow the
requirements specified in Section 5.1, Section 5.4,
and in Figure 8-1.
During power-up, LVCMOS input
pins must not be driven high until after VDD have settled at the
operating voltages listed in Section 5.4.