SBAU413A october 2022 – may 2023
After unpacking, the EVM is configured with the default jumper settings. Figure 5-1 shows the locations for the default jumpers and Table 5-1 shows the functions of the default shunts.
| Designator | Position | Function |
|---|---|---|
| JP1 | [1-2] | RCAPA is selected as bias voltage for the TMP61 |
| JP2 | [2-3] | Selects the transformer output as the APWR supply |
| JP3 | [2-3] | Selects the transformer output as the DPWR supply |
| JP4 | Not installed | The transformer driver is enabled |
| JP5 | Installed | The onboard crystal oscillator is disabled |
Table 5-2 lists the nominal voltages that result from the default configuration.
| Supply Name | Voltage |
|---|---|
| ISO_VCC | 3.3 V |
| ISO_3V3 | 3.3 V |
| VADC_HV | 5.1 V |
| APWR | 5.1 V |
| DPWR | 5.1 V |
| AVDD | 3.3 V |
| DVDD | 3.3 V |
| RCAPA | 1.25 V |
| RCAPB | 1.25 V |