SBOSA33C September 2021 – June 2026 LMH5485-SP
PRODUCTION DATA
When the PD pin is asserted high, close to the positive supply, the device is in normal active mode of operation. To disable the device for reduced power consumption, assert the PD low, close to the negative supply. Figure 6-22 shows the PD pin voltage and the corresponding quiescent current drawn. For applications that require the device to only be powered on when the supplies are present, tie the PD pin to the positive supply voltage.
The disable operation is referenced from the negative supply (normally, ground). For split-supply operation, with the negative supply below ground, a disable control voltage below ground is required to turn the LMH5485-SP off when the negative supply exceeds –0.7V.
For single-supply operation, a minimum of 1.7V greater than the negative supply (ground, in this case) is required for proper operation. This minimum logic-high level allows for direct operation from 1.8V supply logic.