SBVS220C March 2013 – October 2026 TPS7A37
PRODUCTION DATA
Figure 7-11 gives the connections for the adjustable output version, TPS7A3701 (1).
R1 and R2 can be calculated for any output voltage using the formula shown in Figure 7-11. Sample resistor values for common output voltages are shown in Figure 6-2.
For best accuracy, make the parallel combination of R1 and R2 approximately equal to 19kΩ. This 19kΩ, in addition to the internal 8kΩ resistor, presents the same impedance to the error amp as the 27kΩ bandgap reference output. This impedance helps compensate for leakages into the error amp terminals.
Figure 7-11 Typical Application Circuit for Adjustable-Voltage Version(1)