over operating free-air temperature range (unless otherwise
noted)(1)
|
MIN |
MAX |
UNIT |
| VCC
|
Supply voltage range |
|
−0.5 |
7 |
V |
| VI
(2) |
Input voltage range |
|
−0.5 |
VCC + 0.5 |
V |
| VO(2) |
Output voltage range |
|
−0.5 |
VCC + 0.5 |
V |
| IIK |
Input clamp current |
(VI < 0 or VI >
VCC) |
|
±20 |
mA |
| IOK |
Output clamp current |
(VO < 0 or VO >
VCC) |
|
±20 |
mA |
| IO |
Continuous output current |
(VO = 0 to VCC) |
|
±50 |
mA |
|
Continuous current through VCC or GND |
|
|
±200 |
mA |
| Tstg
|
Storage temperature range |
|
−65 |
150 |
°C |
(1) Operation outside the Absolute Maximum Ratings may cause
permanent device damage. Absolute Maximum Ratings do not imply functional operation
of the device at these or any other conditions beyond those listed under Recommended
Operating Conditions. If used outside the Recommended Operating Conditions but
within the Absolute Maximum Ratings, the device may not be fully functional, and this
may affect device reliability, functionality, performance, and shorten the device
lifetime.
(2) The input and output voltage ratings may be exceeded if the input and output current ratings are observed.