SCAS898C May 2010 – May 2026 CDCLVD1204
PRODUCTION DATA
The CDCLVD1204 supports high temperatures on the printed circuit board (PCB) measured at the thermal pad. The system designer must ensure that the maximum junction temperature is not exceeded. ΨJB can allow the system designer to measure the board temperature with a fine gauge thermocouple and back calculate the junction temperature using Equation 1. Note that ΨJB is close to RθJB as 75% to 95% of a device's heat is dissipated by the PCB.
| Example: | ||
| Calculation of the junction-lead temperature with a 4-layer JEDEC test board using four thermal vias: | ||
| TPCB = 105°C | ||
| ΨJB = 19.4°C/W | ||
| PowerinclTerm = Imax × Vmax = 80 mA × 2.625 V = 210 mW (maximum power consumption including termination resistors) | ||
| PowerexclTerm = 202 mW (maximum power consumption excluding termination resistors, see Power Consumption of LVPECL and LVDS (SLYT127) for further details) | ||
| ΔTJ = ΨJB × PowerexclTerm = 19.4°C/W × 202 mW = 3.92°C | ||
| TJ = ΔTJ + TChassis = 3.92°C + 105°C = 108.92°C (maximum junction temperature of 125°C is not violated) | ||
Further information can be found at Semiconductor and IC Package Thermal Metrics (SPRA953) and Using Thermal Calculation Tools for Analog Components (SLUA566).