SCLS697B October   2005  – January 2025 SN74AHC573-Q1

PRODUCTION DATA  

  1.   1
  2. Features
  3. Description
  4. Pin Configuration and Functions
  5. Specifications
    1. 4.1  Absolute Maximum Ratings
    2. 4.2  ESD Ratings
    3. 4.3  Recommended Operating Conditions
    4. 4.4  Thermal Information
    5. 4.5  Electrical Characteristics
    6. 4.6  Timing Requirements, VCC = 3.3V ± 0.3V
    7. 4.7  Timing Requirements, VCC = 5V ± 0.5V
    8. 4.8  Switching Characteristics, VCC = 3.3V ± 0.3V
    9. 4.9  Switching Characteristics, VCC = 5V ± 0.5V
    10. 4.10 Operating Characteristics
  6. Parameter Measurement Information
  7. Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Device Functional Modes
  8. Application and Implementation
    1. 7.1 Power Supply Recommendations
    2. 7.2 Layout
      1. 7.2.1 Layout Guidelines
      2. 7.2.2 Layout Example
  9. Device and Documentation Support
    1. 8.1 Documentation Support
      1. 8.1.1 Related Documentation
    2. 8.2 Receiving Notification of Documentation Updates
    3. 8.3 Support Resources
    4. 8.4 Trademarks
    5. 8.5 Electrostatic Discharge Caution
    6. 8.6 Glossary
  10. Revision History
  11. 10Mechanical, Packaging, and Orderable Information

Electrical Characteristics

over recommended operating free-air temperature range (unless otherwise noted)
PARAMETERTEST CONDITIONSVCCTA = 25°C–40°C to
125°C
–40°C to
85°C
UNIT
MINTYPMAXMINMAXMINMAX
VOHIOH = –50μA2V1.921.91.9V
3V2.932.92.9
4.5V4.44.54.44.4
IOH = –4mA3V2.582.482.48
IOH = –8mA4.5V3.943.83.8
VOLIOL = 50μA2V0.10.10.1V
3V0.10.10.1
4.5V0.10.10.1
IOL = 4mA3V0.360.50.44
IOL = 8mA4.5V0.360.50.44
IIVI = 5.5V or GND0V to 5.5V±0.1±1±1μA
IOZVI = VIL or VIH,VO = VCC or GND5.5V±0.25±2.5±2.5μA
ICCVI = VCC or GND,IO = 05.5V44040μA
CiVI = VCC or GND5V2.51010pF
CoVO = VCC or GND5V3.5pF