SDAA449 November   2026 DP83C8512

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1DP83C8512/8522/8201/1111 Application Overview
  5. 2Troubleshooting the Application
    1. 2.1 Schematic and Layout Checklist
    2. 2.2 Device Health Checks
      1. 2.2.1 Voltage Checks
      2. 2.2.2 Probe the RESET_N Signal
      3. 2.2.3 Probe RBIAS and CEXT
      4. 2.2.4 Probe the XI Clock
      5. 2.2.5 Probe the Strap Pins During Initialization
      6. 2.2.6 Probe the Serial Management Interface Signals (MDC, MDIO)
        1. 2.2.6.1 Read and Check Register Values
          1. 2.2.6.1.1 Extended Register Access
    3. 2.3 MDI Health Checks
      1. 2.3.1 Magnetics
      2. 2.3.2 Probe the MDI Signals
      3. 2.3.3 Link Quality Check
      4. 2.3.4 Compliance
    4. 2.4 MII Health Checks
      1. 2.4.1 MII Check
      2. 2.4.2 RMII Check
    5. 2.5 Loopback and PRBS
      1. 2.5.1 Loopback Modes
      2. 2.5.2 Transmitting and Receiving Packets With the MAC
      3. 2.5.3 Transmitting and Receiving Packets With BIST
  6. 3Summary
  7. 4References

Read and Check Register Values

If applicable, Station Management Interface can be useful in providing valuable status fields during a debug. However, verify that this communication is accurate to avoid compounding issues. Make sure that MDIO has a pull up resistor to VDDIO as this pin is an open-drain to the PHY. When idle, the voltage needs to be VDDIO. Make sure the SMI access follows the following sequence:
 SMI Read OperationFigure 2-7 SMI Read Operation
 SMI Write OperationFigure 2-8 SMI Write Operation
Read the registers and verify the default values shown in the data sheet. Note that the initial values of some registers can vary based on strap options. The expected register values for PHY operation and link in 10/100 Mbps with auto-negotiation enabled are shown in Table 2-4.
Table 2-4 Register Value References
REGISTER ADDRESSREGISTER VALUEComments
10Mbps100Mbps
0x00003100Auto-Negotiation Control, MII Loopback
0x0001786DLink Status
0x0010 4717 or 00174715 or 0715PHY Status
0x00110108PWDN/INT
0x00150000RX Error Counter

With the PHY linked in a given speed, use these values as a reference to identify any variance from the expected operation. Note that not all registers need to be the same, for example the value of register 0x0001 depends on whether the PHY is linked up or not.

Example: After powering and linking the PHY in 10Mbps, Reg 0x10 is read at Reg 0x17. Meaning Bits [4, 2, 1, 0] are high. These bits confirm: Auto-Negotiation is complete, Full-Duplex, 10Mbps Mode, and valid link established.

Repeating this process for any values distinct from the expected values shown in Table 2-4 help diagnose the exact state of the PHY for any encountered issues.