SDAA449 November 2026 DP83C8512
| REGISTER ADDRESS | REGISTER VALUE | Comments | |
|---|---|---|---|
| 10Mbps | 100Mbps | ||
| 0x0000 | 3100 | Auto-Negotiation Control, MII Loopback | |
| 0x0001 | 786D | Link Status | |
| 0x0010 | 4717 or 0017 | 4715 or 0715 | PHY Status |
| 0x0011 | 0108 | PWDN/INT | |
| 0x0015 | 0000 | RX Error Counter | |
With the PHY linked in a given speed, use these values as a reference to identify any variance from the expected operation. Note that not all registers need to be the same, for example the value of register 0x0001 depends on whether the PHY is linked up or not.
Example: After powering and linking the PHY in 10Mbps, Reg 0x10 is read at Reg 0x17. Meaning Bits [4, 2, 1, 0] are high. These bits confirm: Auto-Negotiation is complete, Full-Duplex, 10Mbps Mode, and valid link established.
Repeating this process for any values distinct from the expected values shown in Table 2-4 help diagnose the exact state of the PHY for any encountered issues.