SDAA482 September 2026 BQ25756
The following section gives information about the relation between these different losses. The relations between the variables is the most important rather than calculating the actual magnetic losses of the inductor.
Resistance losses are the easiest to start with and can be expressed with Equation 10:
Where:
At high frequencies, losses from the skin effect and the proximity effect start to take effect. At high frequencies, eddy currents in the conductor cause current to only flow along the outside of the wire. This is called the skin effect. The skin effect can be calculated with Equation 11:
Where:
The conductivity of copper, ρ, is 1.724×10-6 Ω×cm at 25°C and 2.3×10-6 Ω×cm at 100°C. The relative magnetic permeability of copper is 1.
At 100°C, Equation 11 can be simplified to Equation 12:
RACR is directly proportional to RDCR. If the conductor is a wire and conductor thickness >> δ , Equation 13 can be used to estimate the equivalent AC resistance.
For example, consider a 18awg wire (1.037mm) at 250kHz. The penetration depth is 150µm and RACR is 6.8RDCR.
The skin effect and corresponding losses need to be calculated for all frequency components of ΔI.
Finally, there is a third form of loss from the proximity effect. Magnetic fields in the inductor induce eddy currents in both the core material and the wires themselves. In the inductor's windings, these eddy currents can cause ohmic losses even if the wire is not carrying current. These eddy currents also cause current flow in the wire to shift. It's not possible for most engineers to calculate the proximity effect losses.