Setup

Typical test equipment for phase noise and jitter is Agilent E5052 and R&S FSPW. Figure 3-3 shows the preferred way to measure differential output phase noise for signals below 1GHz.

  • Differential output: rejects common mode noise and provides a bigger signal swing.
  • Balun: converts differential signals to single ended output to interface with the analyzer.
  • AC-coupled, or so-called DC blocker: blocks any DC signal going into the equipment and prevents instrument damage. RF Instruments do not accept DC.
LMX2581 Differential Clocking Test
          Setup Figure 3-3 Differential Clocking Test Setup

However, for signals higher than 1GHz, balun is not required. Single-ended measurement is sufficient.