10 Revision History
Changes from Revision A (October 2024) to Revision B (June 2026)
- VDIFF absolute maximum rating expanded to ±40VGo
- Updated the ESD Ratings to include corner pin CDM performance valuesGo
- Unified thermal shutdown values into Power Supply Characteristics
Go
- Added TXD = 250kHz, 1MHz, 2.5MHz in test condition for VSYM
Go
- Added VCC = VIO = GND in test condition for ILKG(IOFF)
Go
- Clarified VHYS, RDIFF, and RSE_CANx descriptionsGo
- Updated "Minimum Data Rate" equationGo
Changes from Revision * (October 2024) to Revision A (October 2024)
- Revision A is the first public release of the data sheetGo
- Added HBM , CDM, and Contact discharge information to the Features listGo
- Added the Dissipation Rating tableGo
- Changed the operating conditions from: TJ = -40℃ to 125℃
to: TJ = -40℃ to 150℃ in the Electrical Characteristics and
Switching Characteristics tablesGo
- Updated Typical Characteristics plotsGo
- Updated Application Curve plotsGo