over free-air temperature range (unless otherwise noted) | MIN | MAX | UNIT |
|---|
| IZ | Continuous cathode current | –10 | 20 | mA |
| TJ | Operating virtual junction temperature | | 150 | °C |
| Tstg | Storage temperature range | –65 | 150 | °C |
(1) Stresses beyond those listed under Absolute Maximum Ratings can cause
permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated
under Recommended Operating Conditions is not implied. Exposure to
absolute-maximum-rated conditions for extended periods can affect device
reliability.