SLUS168F April 1999 – July 2025 UCC2808-1 , UCC2808-2 , UCC3808-1 , UCC3808-2
PRODUCTION DATA
When VCC becomes above 12.5V (for UCCx808-1) or 4.3V (for UCCx808-2), the device is enable, and after all fault conditions are cleared, the gate driver starts with soft-start. When VCC drops below 8.3V (for UCCx808-1) or 4.1V (for UCCx808-2), the device enters the UVLO protection mode and both gate drivers are actively pulled low.