SLVSGD3C December 2022 – October 2026 TPS281C30
PRODUCTION DATA
| PIN | TYPE(1) | DESCRIPTION | |
|---|---|---|---|
| NAME | RGW | ||
| GND | 18 | P | Ground of device. Connect to resistor- diode ground network to have reverse polarity protection. |
| EN | 15 | I | Input control for channel activation. Internal pulldown. |
| DIAG_EN | 16 | I | Enable-disable pin for diagnostics and current sensing. Internal pulldown. |
| FAULT | 17 | O | Open drain global fault output. Referred to FLT, or fault pin. |
| OL_ON | 19 | I | Enable-disable pin for higher resolution current sense(Only available when IOUT< IKsns2_EN). Internal pulldown. |
| SNS | 20 | O | Analog current output corresponding to load current. Connect a resistor to GND to convert to voltage. |
| ILIM | 1 | O | Adjustable current limit. Connect a resistor to set the current limit. Optionally short to ground or leave pin floating to set the current limit to the default internal current limit. See the electrical characteristics for more information. |
| NC | 2, 7, 8, 9, 14 | N/A | No internal connection. |
| VOUT | 3, 4, 5, 6 | P | Output of high side switch, connect to load. |
| VS | 10, 11, 12, 13 | P | Power supply input. |
| Pad | Pad | — | Thermal pad, internally shorted to ground. |