Only the high-side device is protected
under this connection. The load reverse loop is limited by the load itself. Note
when reverse polarity occurs, the continuous reverse current through the power FET
must be less than Irev. Of the three types of ground pin networks, TI
strongly recommends type three (the resistor and diode in parallel). No matter what
types of connection are between the device GND and the board GND, if a GND voltage
shift occurs, confirm the following proper connections for the normal operation:
- Leave the NC pin floating or
connect to the device GND. TI recommends to leave floating.
- Connect the current limit
programmable resistor to the device GND.
- Type 1 (resistor): The higher
resistor value contributes to a better current limit effect when the reverse
battery or negative ISO pulses. However, this leads to higher GND shift during
normal operation mode. Also, consider the resistor power dissipation.
Equation 9.
Equation 10.
where
- VGNDshift is
the maximum value for the GND shift, determined by the HSS and
microcontroller. TI suggests a value ≤ 0.6V.
- Inom is the
nominal operating current.
- –VCC is the
maximum reverse voltage seen on the battery line.
- –IGND is the
maximum reverse current the ground pin can withstand, which is available
in Section 6.1.
If multiple high-side
power switches are used, the resistor can be shared among devices.
- Type 2 (diode): A diode is needed
to block the reverse voltage, which also brings a ground shift (approximately
600mV). However, an inductive load is not acceptable to avoid an abnormal status
when switching off.
- Type 3 (resistor and diode in
parallel [recommended]): A peak negative spike can occur when the inductive load
is switching off, which can damage the HSD or the diode. So, TI recommends a
resistor in parallel with the diode when driving an inductive load. The
recommended selection are 1.5kΩ resistor in parallel with an IF >
100mA diode. If using multiple high-side switches, share the resistor and diode
among devices.