SLVSK29 February 2026 TPS564252B , TPS564255B , TPS564257B , TPS564257C
PRODUCTION DATA
The TPS56425xx can support large duty operations up to 97% by smoothly dropping down the switching frequency. When VIN / VOUT < 1.6 and VFB is lower than internal VREF, the switching frequency is allowed to smoothly drop to make tON extended to implement the large duty operation and improve the performance of the load transient. Please refer to the frequency test waveform in Figure 5-9. The minimum switching frequency is limited to approximately 200kHz.