SLVSK30 February 2026 TPS562242B , TPS563247
PRODUCTION DATA
The TPS56x24x can support large duty operations up to 95% by smoothly dropping down the switching frequency. When VIN / VOUT < 1.6 and VFB is lower than internal VREF, the switching frequency is allowed to smoothly drop to make tON extended to implement the large duty operation and improve the performance of the load transient. Please refer to the frequency test waveform in Figure 5-8. The minimum switching frequency is limited to approximately 450kHz.