SLVSKK8A August 2026 – November 2026 LM7311
PRODUCTION DATA
The following table summarizes the device response to various fault conditions.
| EVENT | PROTECTION RESPONSE | FAULT LATCHED INTERNALLY | FLT PIN STATUS | DEVICE BEHAVIOR AFTER FAULT IS REMOVED |
|---|---|---|---|---|
|
Overtemperature |
Shutdown after TSD threshold |
Y |
L |
Auto Retry(LM7311A) |
| Latch off (LM7311L) | ||||
|
Undervoltage (UVP or UVLO) on VIN or EN |
Shutdown |
N |
H |
Restart |
|
Input Overvoltage |
Shutdown after TOVLOdeb |
Y |
L |
Latch off for both LM7311L and LM7311A |
|
Output Short-Circuit to GND |
Circuit Breaker followed by Current Limit |
N |
H |
Auto Retry. |
| Y after TSD | L after TSD | If TSD is hit during Current limit device behavior is Auto retry (LM7311A) or Latch off (LM7311L) depending on the variant | ||
|
Reverse Current (VOUT - VIN)) > VREVTH) |
Reverse Current Blocking |
N |
H |
Restart |
Faults which are not latched internally are automatically cleared once the trigger condition goes away and thereafter the device recovers without any external intervention. Faults which are latched internally can be cleared either by power cycling the part (pulling VIN to 0V and then above VUVP(R)) or by pulling the EN/UVLO pin voltage below VSD(F)
Fault pin has a readback function. Pulling FLT pin low externally also turns off the device. The FLT pins of multiple eFuses can be tied up together tor turning them all off if one of them has a fault.