Efficiency Data

Efficiency data is shown in Table 2-1.

Table 2-1 Efficiency Data

Input

Output

Total

Voltage (V)

Current (mA)

Power (W)

Voltage (V)

Current (mA)

Power (W)

Loss (W)

Efficiency (%)

47.94

184.2

8.83

954.7

5.16

4.93

3.90

55.79

47.94

292.1

14.00

954.8

10.18

9.72

4.28

69.41

47.94

402.1

19.28

954.8

15.55

14.85

4.43

77.02

47.94

499.1

23.93

954.8

20.20

19.29

4.64

80.61

47.94

613.8

29.43

954.8

25.14

24.00

5.42

81.57

47.94

729.6

34.98

954.8

30.01

28.65

6.32

81.92

47.94

846.0

40.56

954.8

35.16

33.57

6.99

82.77

47.94

996.0

47.75

954.8

42.50

40.58

7.17