Frequency Selection (J7: TON Select)

The operating frequency can be set by J7 TON Select (TONSEL).

Default setting is 300 kHz.

Table 5-2 Frequency Selection
Jumper Set toTONSELFrequency (kHz)
Top (1–2 pin shorted)5VFILT500
Second (3–4 pin shorted)3.3VBIAS350
Third (5–6 pin shorted)VREF300
Bottom (7–8 pin shorted)GND250