SLVUCF6A July   2023  – August 2026

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
  5. 2Requirements
    1. 2.1 Hardware
    2. 2.2 Software
  6. 3TPS65219 Resources Overview
  7. 4EVM Configuration
    1. 4.1 Configuring the USB to I2C Adapter
    2. 4.2 Configuration Headers
    3. 4.3 Test Points
  8. 5NVM Programming
    1. 5.1 TPS6521905 Default NVM Settings
    2. 5.2 NVM Programming in Initialize State
  9. 6Graphical User Interface (GUI)
    1. 6.1 I2C Communication Port and Adapter Debugging
    2. 6.2 Getting Started
      1. 6.2.1 Finding the GUI
      2. 6.2.2 Downloading the Required Software
      3. 6.2.3 Launching the GUI
      4. 6.2.4 Connecting to the EVM
    3. 6.3 Collateral Page
    4. 6.4 Register Map Page
    5. 6.5 NVM Configuration Page
      1. 6.5.1 NVM Fields
      2. 6.5.2 Create and Load a Custom Configuration
    6. 6.6 Sequence Configuration
    7. 6.7 NVM Programming Page
    8. 6.8 Additional Features
  10. 7Schematics, PCB Layouts, and Bill of Materials
    1. 7.1 TPS65219EVM-SKT Schematic
    2. 7.2 TPS65219EVM-SKT PCB Layers
    3. 7.3 TPS65219EVM-RSM Schematic
    4. 7.4 TPS65219EVM-RSM PCB Layers
    5. 7.5 Bill of Materials
  11. 8Revision History

Hardware

This section lists the minimum hardware requirements needed to operate the EVM.

  • EVM
    • One of the TPS65219EVM socket boards listed in Table 2-1:

    • Table 2-1 TPS65219EVM Socket Boards
      Socket Board Part NumberIncluded PMICPackage Size
      TPS65219EVM-SKTTPS6521905RHBR5mm x 5mm
      TPS65219EVM-RSMTPS6521905RSMR4mm x 4mm
    • Note: The socketed EVM can be used for re-programming and basic tests (For example: measuring output voltages, collecting power-up sequence waveforms, and so on) but must not be used to test specific performance parameters like load transient and efficiency because the socket pins and the layout of the socket introduce parasitic that do not represent conditions on real applications.
  • Host Computer
    • A computer with an available USB port is required to make use of the EVM software. The EVM software runs on the computer and communicates with the EVM via a USB-A to micro-B cable.

  • Power Supply
    • A 5V DC power supply is required to power the EVM when using an external supply for VSYS. The TPS65219 socketed EVM also has the option to supply VSYS with the 5V coming from the uUSB cable.