SLVUD61 December   2025

 

  1.   1
  2.   Description
  3.   Get Started
  4.   Features
  5.   Applications
  6.   6
  7. 1Evaluation Module Overview
    1. 1.1 Introduction
    2. 1.2 Kit Contents
    3. 1.3 Specifications
    4. 1.4 Device Information
      1. 1.4.1 Application Circuit Diagram
      2. 1.4.2 IBB Maximum Output Current
  8. 2Hardware
    1. 2.1 Test Setup and Procedure
      1. 2.1.1 EVM Connections
      2. 2.1.2 Test Equipment
      3. 2.1.3 Recommended Test Setup
        1. 2.1.3.1 Input Connections
        2. 2.1.3.2 Output Connections
      4. 2.1.4 Test Procedure
        1. 2.1.4.1 Line and Load Regulation and Efficiency
  9. 3Implementation Results
    1. 3.1 Performance Data and Results
      1. 3.1.1 Conversion Efficiency
      2. 3.1.2 Operating Waveforms
      3. 3.1.3 Bode Plot
      4. 3.1.4 CISPR 25 EMI Performance
      5. 3.1.5 Thermal Performance
  10. 4Hardware Design Files
    1. 4.1 Schematic
    2. 4.2 PCB Layout
      1. 4.2.1 Component Drawings
      2. 4.2.2 Multi-Layer Stackup
    3. 4.3 Bill of Materials
  11. 5Compliance Information
    1. 5.1 Compliance and Certifications
  12. 6Additional Information
    1. 6.1 Trademarks
  13. 7Related Documentation
    1. 7.1 Supplemental Content
      1. 7.1.1 Development Support
      2. 7.1.2 IBB Design Resources
      3. 7.1.3 PCB Layout Resources
      4. 7.1.4 Thermal Design Resources

Test Equipment

Voltage Source: The input voltage source VIN must be an 80V variable DC source capable of supplying 8A.

Multimeters:

  • Voltmeter 1: Measure the input voltage at VIN_S to GND test point (TP3).
  • Voltmeter 2: Measure the output voltage at GND (TP3) to –VOUT (TP4).
  • Ammeter 1: Measure the input current.
  • Ammeter 2: Measure the output current.

Electronic Load: The load must be an electronic constant-resistance (CR) or constant-current (CC) mode capable of 0A to 6A. For a no-load input current measurement, disconnect the electronic load as the load can draw a small residual current.

Oscilloscope: With the scope set to 20MHz bandwidth and AC coupling, measure the output voltage ripple directly across an output capacitor with a short ground lead normally provided with the scope probe. Place the oscilloscope probe tip on the positive terminal of the output capacitor, holding the ground barrel of the probe through the ground lead to the negative terminal of the capacitor. TI does not recommend using a long-leaded ground connection because this can induce additional noise given a large ground loop. To measure other waveforms, adjust the oscilloscope as needed.

Safety: Use caution when touching any circuits that can be live or energized. Always have ESD protection.